Share
Sign In
PML EXAMPLES
Start TTY In E3D Module
B
Bito
👍
간혹 E3D Design 모듈 내에서 TTY를 실행해야하는 경우가 있기에 만들어보았습니다
define function !!StartTTY(!PW IS STRING, !MAC IS string) !InstalledDir = |%pdms_installed_dir%| !Version = !!MODULE().PRODUCT !MODULE = |TTY | VAR !ID USER VAR !PJTCODE PROJECT CODE VAR !MDB MDB if (MATCHWILD(!Version, '*E3D*') ) then !RUN = |CALL | + !InstalledDir + |\mon.exe PROD E3D init | + !InstalledDir + |\launch.init | + !MODULE + !PJTCODE + | | + !ID + |/| + !PW + | | + !MDB + | | + !MAC elseif (MATCHWILD(!Version, '*PDMS*') ) then !RUN = !InstalledDir + |\pdms.bat | + !PJTCODE + | | + !ID + |/| + !PW + | | + !MDB + | | + !MODULE + !MAC ENDIF SYSCOM 'START /MIN cmd.exe /C $!RUN' endfunction
Bi
Subscribe to 'bittokki'
Welcome to 'bittokki'!
By subscribing to my site, you'll be the first to receive notifications and emails about the latest updates, including new posts.
Join SlashPage and subscribe to 'bittokki'!
Subscribe
👍
Other posts in 'PML EXAMPLES'See all
Bito
엑셀추출
Bito
특정 Type만 Delete
특정 Type 만 delete 하기 위해 생성했습니다 상황에 따라 수정하여 사용하면 될것같습니다.
Bito
Output CE(Type 하위 값만 Datal)
!!OutputCe() 의 경우 선택한 값을 DALTAL 하기위해서 사용하는데 선택한 위치에서 원하는 TYPE 하위의 값만 DALTAL 하기위해서 추가로 생성해보았습니다 기본적인 Output CE 하위 Type 만 Datal